- Expect reflection of dynamic cracks and control joints in substrate. Implement detail as per current published installation guidelines (IG’s).
- Staining, streaking and efflorescence may occur when fresh coating is exposed to excessive ponding or running water.
- As with all cement-based materials, avoid any contact with aluminum which can cause an adverse reaction due to Miracote MPC’s cementitious content. If unavoidable, prime aluminum with MiraPrime Membrane B.
- Concrete structures or elements containing hydrophobic crystalline admixtures may result in substrates that will be difficult to produce acceptable adhesion. Perform in-situ pulloff testing to verify suitable and measurable tensile bond strengths.
| - Use extreme caution when resurfacing scaled concrete surfaces in freeze-thaw zones due to the potential for insufficient air-entrainment. These types of unsound surfaces may continue to scale at the bond line due to migration of ground moisture.
- Reported product technical data published in this document is based on controlled laboratory tests conducted in controlled conditions. Actual field installed properties and final appearance may vary due to climatic conditions, mixing and application methods, equipment, application and curing conditions, and independent test methods.
- After a heavy, pro-longed downpour or following pressure washing operations concrete substrates should be allowed to sufficiently vacate excess moisture prior to proceeding with the application.
|